{"id":2981,"date":"2020-06-29T14:43:38","date_gmt":"2020-06-29T09:13:38","guid":{"rendered":"https:\/\/rightactionglobal.com\/?post_type=product&p=2981"},"modified":"2020-07-15T11:55:35","modified_gmt":"2020-07-15T06:25:35","slug":"lpcb-addressable-manual-call-point-aw-d305-for-fire-alarm-system","status":"publish","type":"product","link":"https:\/\/rightactionglobal.com\/product\/lpcb-addressable-manual-call-point-aw-d305-for-fire-alarm-system\/","title":{"rendered":"LPCB Addressable Manual Call Point D305 for Fire Alarm System"},"content":{"rendered":"

The AW-D305 Addressable manual call point ( hereinafter referred to AW-D305 Addressable) is mainly designed to be used with an intelligent two-bus control system. If it is pressed after a fire is manually confirmed, an alarm signal may be sent to a fire alarm control system which will, after receiving the alarm signal, display the coded address and the equipment status of the manual fire call points. When the manual fire call points is operating normally, the red indicator will blink; when there is a fire alarm, it will remain lit. The AW-D305 Addressable supports electronic coding, more suitable for engineering application convenient.<\/p>\n

Addressable Manual Call Point features\uff1a<\/strong><\/h2>\n
1. Semi-flush or surface mounting<\/div>\n
2. Compatible with the latest EN standards<\/div>\n
3. Lever reusable ( non-glass break )<\/div>\n
4. LED indicator<\/div>\n
5. Full electronic coding, through CODER-9001 encoder scene rewrite<\/div>\n
<\/div>\n
\n

Addressable Manual Call Point\u00a0Technical Parameters\uff1a<\/strong><\/h2>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
Operating Voltage<\/td>\nSignal Loop 24V(18V\uff5e28V)
\nPower 24VDC(20VDC\uff5e28VDC)<\/td>\n<\/tr>\n
Standby Current<\/td>\nLoop\uff1c0.8mA ; Power\uff1c2mA<\/td>\n<\/tr>\n
Action Current<\/td>\nLoop\uff1c5mA ; Power\uff1c15mA<\/td>\n<\/tr>\n
Output Capacity<\/td>\n1A@DC30V<\/td>\n<\/tr>\n
Input Mode Setting<\/td>\nNC or NO input mode can be set by the jumper JP4.<\/td>\n<\/tr>\n
Programming Method<\/td>\nElectronically addressed<\/td>\n<\/tr>\n
Code Range<\/td>\nOne address within 1~324.<\/td>\n<\/tr>\n
Indicators<\/td>\nInspection indicator: l blink once about every 12 seconds in the inspection status or remain lit in the output status;
\nInput indicator : remain lit in the feedback status.<\/td>\n<\/tr>\n
Operating Temperature<\/td>\n-10\u2103\uff5e+55\u2103<\/td>\n<\/tr>\n
Relative Humidity<\/td>\n\u226495% , non-condensing<\/td>\n<\/tr>\n
Material of Enclosure<\/td>\nABS<\/td>\n<\/tr>\n
Dimension (L\u00d7W\u00d7H)<\/td>\n86mm\u00d786mm\u00d741mm
\n(with base)<\/td>\n<\/tr>\n
Mounting Hole Distance<\/td>\n60.5mm<\/td>\n<\/tr>\n
Weight<\/td>\nAbout 148g (with base)<\/td>\n<\/tr>\n
Operating Voltage<\/td>\nSignal Loop 24V(18V\uff5e28V)
\nPower 24VDC(20VDC\uff5e28VDC)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"

The AW-D305 Addressable manual call point ( hereinafter referred to AW-D305 Addressable) is mainly designed to be used with an intelligent two-bus control system. If it is pressed after a fire is manually confirmed, an alarm signal may be sent to a fire alarm control system which will, after receiving the alarm signal, display the<\/p>\n","protected":false},"featured_media":2982,"template":"","meta":[],"product_cat":[505,552],"product_tag":[],"_links":{"self":[{"href":"https:\/\/rightactionglobal.com\/wp-json\/wp\/v2\/product\/2981"}],"collection":[{"href":"https:\/\/rightactionglobal.com\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/rightactionglobal.com\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/rightactionglobal.com\/wp-json\/wp\/v2\/media\/2982"}],"wp:attachment":[{"href":"https:\/\/rightactionglobal.com\/wp-json\/wp\/v2\/media?parent=2981"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/rightactionglobal.com\/wp-json\/wp\/v2\/product_cat?post=2981"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/rightactionglobal.com\/wp-json\/wp\/v2\/product_tag?post=2981"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}